Nonwoven Liquid Penetration Tester STD-MB03A - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466
Produits

Nonwoven Liquid Penetration Tester STD-MB03A

Test PrincipleA solution of known volume (e.g., artificial urine with a surface tension of 70dy

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenu

Principe d'essai

A solution of known volume (e.g., artificial urine with a surface tension of 70dyn/cm) is placed in a teflon-lined container.A solenoid valve is used to drain the liquid at a constant rate through the center hole of the nonwoven upper plate (through the electrode plate).The two electrodes start the timer with a conductive liquid.The nonwoven sample is placed on a set of 5/10 pieces of filter paper that ACTS as a suction liquid.When all the conductive liquid enters the suction layer, the circuit current will interrupt and stop the timer.EDANA requires the configuration of artificial urine at a rate of 25ml/3.5±0.25s.

Standards

GB/T 24218.14. FZ/T 60017. GB/T 24218.8.EDANA

Features

1. High precision peristaltic pump ensures the accuracy of liquid penetrating capacity.

2. Automatic refueling function, automatic testing throughout the process, no need for manual refueling.

3. The penetrating disc is made of special plexiglass and is guaranteed to be 500 grams ±5 grams after special processing.

4. Automatically save data after completing the test, and check the calculation and analysis results of the report, and print the test report.

5. Touch screen control panel and clear image interface provide more convenient and quick operation for testers.

6. Free access to all data and statistical results in the host.

7. The penetrating disc is equipped with precise positioning device to avoid collision damage.

8. Platinum wire electrode is used for penetrating disc electrode, which is sensitive, precise and durable.

9. Instrument liquid release is equipped with automatic release device, which can realize automatic control and stable flow rate.

Key Specifications

 
ModelSTD-MBO3A
Automatic liquid dosageCan be set from 0.1 to 10.0ml (Settable
Test accuracy0.01s
penetration times1-5 times can be set
Interval time20-99s is adjustable
Size of penetrating disc100x100x25 mm
Total mass of penetrating disc500g+59
The time of Battery valve's funnel flow rate 25ml3.5s+0.3s
Power supplyAC 220V 50Hz 100W
Extemal dimension400x375x520mm
ConnectionOptional USB communication, connect to the computer
 

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.