DescriptionThe TE 76 is a two-station, vertical axis, long stroke reciprocating tribometer, whi
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
The STD-TE 76 is a two-station, vertical axis, long stroke reciprocating tribometer, which combines the reciprocating drive mechanism and fixed specimen mounting from the TE 77 High Frequency Friction Machine with a UHV test chamber.
Contact Configurations: | Point Contact | |
Line Contact | ||
Area Contact | ||
Load Range: | 5 to 500 N | |
Laboratory Chiller: | -35°C to 150°C | |
Temperature Sensor: | PT-100 | |
Frequency Range: | 2 to 25 Hz | |
Stroke Range: | See following tables | |
Friction Transducer: | Piezo-Electric Type | |
Interface: | Serial Link Interface Module | |
Software: | COMPEND 2000 | |
Motor: | 1.1 kW a.c. vector motor, 2048 ppr encoder | |
Stroke Range | ||
Continuously Variable Cam – 0 to 12.5 mm | ||
Angle – degrees: | Minimum – mm | Maximum – mm |
0 | 0 | 2 |
18 | 1.04 | 3.04 |
36 | 2.65 | 4.65 |
54 | 4.25 | 6.25 |
72 | 5.75 | 7.75 |
90 | 7.09 | 9.09 |
108 | 8.24 | 10.24 |
126 | 9.17 | 11.17 |
144 | 9.85 | 11.85 |
162 | 10.26 | 12.26 |
180 | 10.4 | 12.4 |
Step Variable 0 to 12.5 mm: | ||
Angle – degrees: | Nominal Stroke – mm | |
0 | 0 | |
18 | 1.94 | |
36 | 3.83 | |
54 | 5.63 | |
72 | 7.29 | |
90 | 8.77 | |
108 | 10.03 | |
126 | 11.05 | |
144 | 11.79 | |
162 | 12.25 | |
180 | 12.5 | |
Step Variable 12.5 to 25 mm: | ||
Angle – degrees: | Nominal Stroke – mm | |
0 | 12.5 | |
18 | 13.05 | |
36 | 14.26 | |
54 | 15.97 | |
72 | 17.89 | |
90 | 19.8 | |
108 | 21.54 | |
126 | 23 | |
144 | 24.09 | |
162 | 24.77 | |
180 | 25 | |
Test Chamber | ||
Pressure: | Atmospheric to 100 Picobar (10-5 Pa) | |
Environment: | Air, inert gas or vacuum | |
Material: | 304 stainless steel | |
Surface Treatment: | Glass bead blasted | |
Viewports: | Fused Silica | |
Electrical Feedthrough: | 1 kVolts , 15 Ampere | |
Coaxial Feedthrough: | BNC through Flange | |
Thermocouple: | Type K through Flange | |
Vacuum Transducer: | Cold Cathode and Pirani | |
Laboratory Chiller | ||
Fluid Temperature: | -35°C to +150°C. | |
Automatically Controlled Parameters | Frequency | |
Load | ||
Temperature | ||
Chamber Pressure | ||
Test Duration | ||
Manually Controlled Parameter | Stroke | |
Measured Parameters | Friction | |
Load | ||
Temperature | ||
Chamber Pressure | ||
Frequency | ||
Friction Coefficient | ||
. | ||
Services | ||
Electricity: | 220/240 V, single phase, 50/60 Hz, with neutral and earth, 4.5 kW | |
Clean, dry air: | 4 cfm at 8 bar (120 psi) |
Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.