STD-TE 76 TWO STATION RECIPROCATING VACUUM TRIBOMETER - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466
Produits

STD-TE 76 TWO STATION RECIPROCATING VACUUM TRIBOMETER

DescriptionThe TE 76 is a two-station, vertical axis, long stroke reciprocating tribometer, whi

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenu

Description

The STD-TE 76 is a two-station, vertical axis, long stroke reciprocating tribometer, which combines the reciprocating drive mechanism and fixed specimen mounting from the TE 77 High Frequency Friction Machine with a UHV test chamber.

Technical Specifications

Contact Configurations:Point Contact

Line Contact

Area Contact
Load Range:5 to 500 N
Laboratory Chiller:-35°C to 150°C
Temperature Sensor:PT-100
Frequency Range:2 to 25 Hz
Stroke Range:See following tables
Friction Transducer:Piezo-Electric Type
Interface:Serial Link Interface Module
Software:COMPEND 2000
Motor:1.1 kW a.c. vector motor, 2048 ppr encoder



Stroke Range

Continuously Variable Cam – 0 to 12.5 mm

Angle – degrees:Minimum – mmMaximum – mm
002
181.043.04
362.654.65
544.256.25
725.757.75
907.099.09
1088.2410.24
1269.1711.17
1449.8511.85
16210.2612.26
18010.412.4



Step Variable 0 to 12.5 mm:

Angle – degrees:Nominal Stroke – mm
00
181.94
363.83
545.63
727.29
908.77
10810.03
12611.05
14411.79
16212.25
18012.5
Step Variable 12.5 to 25 mm:

Angle – degrees:Nominal Stroke – mm
012.5
1813.05
3614.26
5415.97
7217.89
9019.8
10821.54
12623
14424.09
16224.77
18025



Test Chamber

Pressure:Atmospheric to 100 Picobar (10-5 Pa)
Environment:Air, inert gas or vacuum
Material:304 stainless steel
Surface Treatment:Glass bead blasted
Viewports:Fused Silica
Electrical Feedthrough:1 kVolts , 15 Ampere
Coaxial Feedthrough:BNC through Flange
Thermocouple:Type K through Flange
Vacuum Transducer:Cold Cathode and Pirani



Laboratory Chiller

Fluid Temperature:-35°C to +150°C.



Automatically Controlled ParametersFrequency

Load

Temperature

Chamber Pressure

Test Duration



Manually Controlled ParameterStroke



Measured ParametersFriction

Load

Temperature

Chamber Pressure

Frequency

Friction Coefficient

.
Services

Electricity:220/240 V, single phase, 50/60 Hz, with neutral and earth, 4.5 kW
Clean, dry air:4 cfm at 8 bar (120 psi)


Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.


Message en ligne

Détails de contact

Téléphone de l'entreprise

+86-21-6420 0566

Heures de travail

Du lundi au vendredi

Téléphone portable:

13816217984

Courriel :

info@qinsun-lab.com

Code QR