The common heat transfer forms of textiles are heat conduction, thermal convection and thermal radia
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
GB/T 41560-2022 (China): Specifies thermal resistance testing protocols for protective clothing and industrial fabrics.
BS 6526:1998 (UK): Defines methodologies for evaluating the thermal insulation properties of textiles under controlled conditions.
ISO 11092: Additional compliance for physiological comfort testing of heat-resistant materials.
Dual-Sensor Accuracy: Simultaneous sample plate and heating block temperature monitoring (±0.1% precision).
Variable Speed Control: Adjustable brass cylinder velocity (1–60 mm/s) for dynamic impact testing.
Bi-Directional Safety: Automatic polyethylene shield deployment (80 mm/s) prevents operator exposure.
Wide Temperature Range: -5°C to 180°C operation for extreme condition simulations.
Global Compliance: Pre-configured GB/T and BS protocols streamline CE/SGS certification.
Compact Footprint: 540 × 380 × 500 mm benchtop design suits QC labs and R&D facilities.
Brass Impact Cylinder: Calibrated 3.000 ±10 g weight with dual-zone temperature sensing (2.5 mm from base).
Precision Temperature Control: 0.1°C resolution PID system maintains stable test conditions.
Sample Alignment System: 70 mm diameter specimen holder with vacuum suction for wrinkle-free placement.
High-Speed Data Logging: 100 kHz sampling rate captures transient thermal events.
Interchangeable Shields: Polyethylene guard plates (200 × 250 × 15 mm) for operator protection.
Intuitive Touchscreen: Pre-loaded GB/T 41560/BS 6526 test sequences with real-time curve plotting.
Brass Impact Assembly:
Tapered cylinder (3.000 ±10 g, ±0.02 mm dimensional tolerance)
Dual K-type thermocouples (0–260°C range, ±0.1% accuracy)
Sample Holder Kit:
Vacuum suction specimen platform (Ø70 mm)
Non-stick PTFE coating prevents thermal bridging
Safety System:
Motorized polyethylene shield (200 × 250 × 15 mm)
Emergency stop button with interlock
Calibration Bundle:
NIST-traceable temperature standard
Velocity verification gauge
Operator Kit:
Insulated tweezers
Sample cutting die (Ø70 mm)
Software Suite:
ThermalGuard Pro for automated report generation
21 CFR Part 11-compliant audit trail
Paramètres | Spécification |
---|---|
Sample Size | Ø70 mm (circular) |
Temperature Range | -5°C–180°C (±0.5°C accuracy) |
Temperature Resolution | 0.1°C |
Brass Cylinder Specs | 3.000 ±10 g |
Cylinder Velocity | 1–60 mm/s (adjustable) |
Safety Shield Deployment | 80 mm/s (automatic at 60°C threshold) |
Taux d'échantillonnage des données | 100.000 samples/second |
Power Supply | AC 220V ±10%, 50Hz, 600W |
Dimensions (L×W×H) | 540 × 380 × 500 mm |
Weight | 40 kg (net) |
Operating Environment | 10°C–40°C, <85% RH |
Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.