STD-TE 86 MULTI-STATION HIP JOINT SIMULATOR - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466
Produits

STD-TE 86 MULTI-STATION HIP JOINT SIMULATOR

IntroductionThe STD-TE 86 Multi-station Hip Joint Simulator is manufactured under licence from Dr V

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenu

Présentation

The STD-TE 86 Multi-station Hip Joint Simulator is manufactured under licence from Dr Vesa Saikko, Laboratory of Machine Design, Department of Mechanical Engineering, Helsinki University of Technology. The device incorporates an electro-mechanical drive and servo-pneumatic loading system. The machine is simple to operate and a very cost-effective solution for multi-station wear testing of prosthetic hip joints. The unit is available with twelve test stations, with a maximum load of 2 kN per test station, or six test stations, with a maximum load of 3 kN per test station.

Description

The STD-TE 86 provides two-axis motion with the prosthesis samples mounted in the appropriate anatomical position. The acetabular cup is located above the femoral head so that in the neutral position, the symmetry axes of both the head and the cup are at an angle of 45 degrees to the vertical. This angle can be varied, if required, without difficulty, by varying the design of the tooling.

Technical Specifications




Test Configuration:Acetabular cup on femoral head
Number of Test Stations:6 or 12
Test Frequency:1.06 Hz (with 50 Hz supply)

1.27 Hz (with 60 Hz supply)
Maximum Load:3 kN (6 station) or 2 kN (12 station)
Minimum Load:0.4 kN
Average Load:1.2 kN
Flexion-extension (FE):46 degrees
Abduction-adduction (AA):12 degrees
Force Track Aspect Ratio:3.8
Force Track Length:1.73r (where r is head radius)
Motor Power:370 W
Fluid Volume:500 ml


Controlled ParametersTest Load

Number of Cycles


Services
Electricity:1.5 kW 240 volt 50 Hz single phase plus neutral

1.5 kW 110 volt 60 Hz single phase plus neutral
Compressed Air:4 cfm at 8 bar (typical)


Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.