**Scope of Application**Determines the liquid loss performance of nonwoven fabrics. Place a standard
Courriel : info@standard-groups.com
**Scope of Application**
Determines the liquid loss performance of nonwoven fabrics. Place a standard absorbent medium beneath the test specimen, position the combined sample on an inclined platform, and measure the liquid penetration through the nonwoven fabric into the absorbent medium when a specific volume of artificial urine flows downward. Calculate the liquid loss performance by weighing the absorbent medium before and after testing.
**Compliance Standards**
Edana 152.0-99; ISO 9073-11
**Technical Specifications**
1. Test bench features two black reference lines:
- Low line: Located 3±0.2 mm above the bench end (absorbent medium position)
- High line: Approximately 25 mm below specimen top (aligns with drainage tube center)
2. Bench inclination: 25°
3. Clamp assembly:
- Adjustable device for fixing specimens symmetrically at (140±0.2) mm from reference line
4. Central positioning mechanism
5. Absorbent pad support frame at specimen lower edge
6. Glass tube specifications:
- Inner diameter: 5 mm
7. Ring-shaped base plate
8. Drip feeding system:
- Delivers (25±0.5) g test liquid continuously through glass tube in (4±0.1) seconds
Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.