Wet leakage current test system of photovoltaic module - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466

Wet leakage current test system of photovoltaic module

Purpose:Test the insulation performance of the components under wet working conditions to verify tha

Courriel : info@standard-groups.com

Contenu

Objectif :

Test the insulation performance of the components under wet working conditions to verify that the moisture of rain, fog, dew, water and dissolved snow cannot enter the components and affect the circuit.


Applicable standards:

IEC61215


Technical specifications:

Test tank:

Size :2100x1000x250mm(W*D*H), thickness :15mm; Material: Plexiglass

Temperature control: Hongtu self-developed water constant temperature system, temperature :22+3° C

Liquid resistivity: less than 3500Q.cm

Spray system: UL laboratory special nozzle, multi-directional spray adjustment, water pressure and water flow adjustable


企业微信截图_17422754188261.png

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.