Battery Adiabatic Calorimeter - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466
Produits

Battery Adiabatic Calorimeter

Measures heat generated by batteries under adiabatic conditions for safety tests.

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenu

Reference Standards

GB/T 36276 - 2023 *Lithium - ion Batteries for Electric Power Energy Storage

UL 9540A ASTM E1981 - 98(2012) SN/T 3078.1 - 2012 *Guidelines for the Evaluation of Thermal Stability of Chemicals - Part 1: Accelerated Calorimetry Method

USABC SAND99 - 0497. July 1999: 3.2 Thermal Stability Tests SAE J2464 - R2009: 4.4.2 Thermal Stability Tests Freedom CAR SAND 2005 - 3123: 4.1 Thermal stability UL 1973 GB 38031 - 2020 *Safety Requirements for Power Batteries of Electric Vehicles


Product Features

Precision: The self - heating detection sensitivity is far better than the standard detection threshold of 0.02°C/min. It has high thermal insulation performance and a small temperature difference between the wall and the sample. Efficiency: With an innovative heating wire assisted heating solution, the experimental efficiency can be increased by up to 5 times. Safety: It is equipped with safety protection measures such as burst discs, pressure relief valves, and explosion - proof boxes. The professional alarm system design comprehensively ensures the safety of personnel and equipment. Innovation: It has the innovative function of adiabatic thermal runaway - gas production combined analysis, enabling a comprehensive acquisition of the characteristic parameters of battery thermal runaway.


Technical parameters:

Adiabatic chamber effective size: diameter 800mm, depth 520mm

Self-exothermic detection sensitivity: better than 0.02℃/min

Constant temperature wall sample temperature difference: ≤ 1℃

Temperature control range: RT ~ 300℃, configuration of low temperature module up to -25℃

Working pressure range: 0 ~ 2MPa

Temperature tracking rate: 0.02 ~ 15℃/min

Needle maximum stroke: stroke software can be set up

Charge and discharge electrode column overcurrent capacity: -1000A ~ 1000A


5636

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.