The high - voltage DC stability tester is suitable for testing DC high - voltage within the range of 0.1 - 5.00KV and continuously recording the values of high - voltage and leakage current of the test samples.

Standard 
Engineered to meet the stringent safety and performance demands of global industries, this High-Voltage DC Stability Tester adheres to IEC 61010-1 (safety requirements for electrical equipment) and UL 61010-1 standards. It is certified for CE compliance and designed to align with AEC-Q100 (automotive grade) and MIL-STD-883 (aerospace) specifications, ensuring seamless integration into regulated testing environments.

Main parameters:

(1) Power: 500VA (2) Power supply: 220V/50HZ (3) High - voltage output range: 0 - 5KV (AC/DC) (4) Leakage current range: 0 - 2/20/100mA (AC), 0 - 2/20mA (DC) (5) Accuracy: ±(3% + 3counts) (6) Test time setting range: 1μs - 999.9S/M/H (7) Voltage adjustment mode: Manual adjustment (8) A digital voltmeter with data communication function (range: 0 - 5.00KV) and a digital ammeter (0.1μA - 3.0mA) are used to realize the data acquisition function of test voltage and leakage current. (9) Issues regarding high - voltage and grounding connections: A. In principle, the wire conductor of the test sample should be connected to the high - voltage, and the saltwater for testing should be grounded, which ensures testing safety. B. It is not recommended to connect the saltwater to the high - voltage and ground the conductor of the test wire. C. The testing equipment must be placed within a safety fence during testing to avoid personal safety accidents. (10) Dedicated software for recording voltage and current data is provided to achieve data storage.

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.

Précédent :Paper Grammage Tester
Page suivante:Paper Dirtiness Tester

Message en ligne

Détails de contact

Téléphone de l'entreprise

+86-21-6420 0566

Heures de travail

Du lundi au vendredi

Téléphone portable:

13816217984

Courriel :

info@qinsun-lab.com

Code QR