Mask & Respirator Breathing Resistance Tester

Respirator Breathing Resistance Tester is used to measure the respiratory resistance and expiratory resistance of respirators and masks under the specified conditions.The flow rate for inhale resistance test is 30L/min and 95L/min.

The flow rate for exhale resistance test is 160L/min. And the flow rate for the flow impact test is 300L/min.Applicable to the national labor protection supplies inspection agency, mask manufacturers related inspection and inspection of ordinary masks, dust masks, medical masks, anti-fog mask products.

Standards

EN149-2009 section 7.15. 8.3.4.

EN 13274-3.

GB 19083.

GB 2626.

NIOSH 42 CFR Part 84.

JIS/T 8151

Maintenance

1. Do not carry it by the bottom of the control box during transportation to avoid being crushed.

2. Please wipe the electroplated part with oil to prevent rust and keep bright.

3. After the test, please wipe the machine clean, and regularly oil the active fulcrum to increase its service life and sensitivity. (The lubricating oil can be mixed with butter and a little engine oil)

4. Please wipe the panel (control box or display) with a dry cloth to prevent it from getting wet, so as not to damage the IC electronic parts.

5. Please place all fixtures and joint accessories properly, and wipe off the anti-rust oil to prevent rust.

Features

1. Touch screen control, English menu, man-machine dialogue mode, easy operation.

2. Built-in thermal printer, it is convenient to quickly print test results on site.

3. Two modes of breath detection and inhalation detection can be set.

4. The automatic switching device of the respirator pipeline solves the problem that the tester pulls out the

pipe and accidentally connects the pipeline when testing.

5. 3D printed standard head mold, which simulates the actual inhalation and exhalation of the human body,

improving the accuracy of the data.

Spécification

1. The instrument consists of an air source that can adjust the flow rate, a human head mold specified in the standard, two intubation systems for inhalation and exhalation, and a respiratory resistance measurement system.

2. The flow sensor has high sensitivity and has a very small starting flow.

3. The flow sensor chip uses a thermal mass flow meter, which does not require temperature and pressure compensation, ensuring high-precision measurement of the sensor. The range of the flow meter is 0 L / min - 100L / min.

4. Multiple sensors are integrated on a single flow sensor chip, which greatly improves the range ratio of the sensor.

5. The zero point stability of the flow sensor is high, with full range and high stability, high accuracy over the full range, excellent repeatability, low power consumption, low pressure loss and fast response speed.

6. The data logger uses a graphic dot matrix LCD with a resolution of 128 * 64 and a full Chinese / English interface, which is easy to operate.

7. the data logger has 4M memory for measurement value recording.

8. The micromanometer sensor uses a two-wire system, with high accuracy and good stability; it is safe and reliable to use an explosion-proof design.

9. The range and zero point of the micromanometer sensor are continuously adjustable, the damping is adjustable, there is no mechanical moving part, and the maintenance workload is small. The micro-pressure measurement range is -1000Pa to 1000Pa, and the accuracy is 1Pa.

10. The whole instrument adopts special gas path conversion elements, which ensures the convenient and fast conversion of the two-pipe system of exhalation and inhalation.

11.The suction volume of the suction pump is not less than 40L / min - 100L / min

12. Ventilation volume is constant at 85 L / min

13. Power supply: AC220V, 50Hz

Mask Breath Respiratory Resistance Tester

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.