Automated Filter Tester 3120 - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466

Automated Filter Tester 3120

Automated Filter Tester Model 3120 meets NIOSH’s proposed Powered Air Purifying Respirator (PAPR) fi

Courriel : info@standard-groups.com

Contenu

Automated Filter Tester Model 3120 meets NIOSH’s proposed Powered Air Purifying Respirator (PAPR) filter test requirements. It is an oil-only tester that has an airflow range of 100 to 200 L/min and can measure efficiencies up to 99.999%, or penetrations as low as 0.001%. In fact, Model 3120 uses the same proven oil-aerosol generator found in models 8127 and 8130. Like models 8127 and 8130, Model 3120 features dual light scattering photometers that simultaneously measure upstream and downstream particle concentration to ensure fast, repeatable results.
 
Application
Automated filter testing
 
Features
◆ A touch-panel display makes the Model 3120 easy to use, so very little operator training is needed. On-screen menus enable users to easily change test parameters to meet specific requirements of different filters. A microprocessor controls the tester and calculates and displays filter penetration, resistance value and flow rate. Self-check diagnostics and automatic zeroing between tests ensures accurate, stable, and reproducible results.
◆ Compliance with respirator regulations
◆ Simple, fast and automated operation
◆ Service and support
 
Components
 Dust removal system:
The compressed filtration air system provides a certain amount of testing dust for the aerosol generator
The test chamber:
Main test chamber and sample clamp
Monitoring and regulating system:
Pressure monitoring and adjustment provide dynamic test environment
Results display and analysis system:
Monitor through aerosol and display test results
 
Paramètres techniques

ProjetsParamètres
Measurement ApplicationLoading and Quality Control Tests
Maximum Efficiency99.999%
Aerosol TypeDOP/PAO/DEHS/Paraffin/other Oils
Aerosol GenerationAtomizer
Count Median Diameter0.2μmm (Oil)
Geometric Standard Deviation<1.6m(Oil)
Flow Rate15-100L/min
Resistance0-150mm H2O(0-1470Pa)
Particle DetectionLight Scattering Photometer
Typical Test Length10s
Data ReportingAlpha-Numeric Display, RS-232
OperationStand Alone Tester/Automated Production Lines
ConformitéUS 42 CFR part 84,EN 143,JMOL,ISO 23328-1

image.png

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.