Advanced Specific Surface Area and Micropore Analyzer

Test PrincipleUnder low temperature conditions (e.g., liquid nitrogen bath, 77.3K), a certain a

Courriel : info@standard-groups.com

Contenu

Principe d'essai

Under low temperature conditions (e.g., liquid nitrogen bath, 77.3K), a certain amount of adsorbate gas (e.g., N₂) is introduced into the sample tube. The adsorption partial pressure is directly measured by controlling the equilibrium pressure in the sample tube, and the adsorption amount at this partial pressure point is obtained through the gas equation of state (PV=nRT). By gradually adding adsorbate gas to increase the adsorption equilibrium pressure, the adsorption isotherm is obtained. By gradually removing adsorbate gas to decrease the adsorption equilibrium pressure, the desorption isotherm is obtained. Compared with the dynamic method, no carrier gas (He) is required, and there is no need to repeatedly raise and lower the liquid nitrogen cup. Since the sample to be tested is in a fixed-volume sample tube, the adsorbate does not flow relative to the dynamic chromatographic method, hence the name static volumetric method.

Paramètres techniques

◆ Test functions: Evaluation of specific surface area, pore structure, and other gas adsorption properties
◆ Types of adsorbates: Testing of various non-corrosive gases
◆ Test range: Specific surface area above 0.0005 m²/g, pore diameter 0.35-500 nm
◆ Number of analysis stations: 1/2 analysis station;
◆ Number of degassing stations: 2 pretreatment stations;
◆ Independence: The testing system and degassing system are independent of each other, allowing simultaneous sample testing and degassing;
◆ Test accuracy: Specific surface area ≤±1.0%, most probable pore diameter repeatability deviation ≤0.15 nm, true density ≤±0.04%, external surface area ≤±1.5
◆ Independent P0 station: Patented independent spiral saturated vapor pressure (P0) test station to ensure high accuracy of partial pressure testing
◆ Temperature-programmed degassing: Software-controlled temperature programming, room temperature-400°C, accuracy better than 0.1°C; (customizable for special requirements)
◆ Ultimate vacuum:
PS series: Original imported two-stage mechanical vacuum pump, vacuum degree 4*10-2 Pa,
PM series: 1 original imported turbomolecular pump + 2 original imported mechanical pumps, P/P0 as low as 10-8
◆ Pressure measurement:
PS series: 1 original imported pressure sensor per test station, range 0-1000 torr
PM series: Multiple pressure sensors per test station, ranges 0-1 torr and 0-1000 Torr (0-0.1 Torr optional);
◆ Open data interface: The software can be integrated with LIMS to upload test results to LIMS.

 Testing Report

6

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.