I. Applicability Scope
This system applies to combustion performance testing of non-metallic materials in aircraft cabins:
- 1.1 Crew/Passenger Cabin Areas:
Including ceiling panels, interior walls, partitions, galley structures, cabinet linings, floor coverings, textiles (curtains/coverings), seat cushions, padding, coated fabrics (decorative/non-decorative), leather products, trays/kitchen equipment, electrical conduits, air ducts, joints/edge covers, B/E class cargo compartment linings, B/C/D/E class cargo floor panels, cargo covers, transparent enclosures, molded/thermoformed components, duct joints/edge trims, etc.
- 1.2 Non-crew/Passenger Cargo Areas:
Insulation blankets, cargo protective covers, tie-down equipment (including containers, ULDs) for each cargo compartment.
II. Compliance Standards
- FAR25.853 (FAA Airworthiness Standards for Transport Category Aircraft)
- CCAR-25-R4.853 (Chinese Civil Aviation Regulations Appendix F Part I)
- HB5469-2014 (Civil Aircraft Cabin Non-metallic Material Combustion Test Method)
- HB5470-2014 (Civil Aircraft Cabin Non-metallic Material Combustion Performance Requirements)
- RTCA/DO-160G Section G26.6.2/G26.6.3/G26.6.4 (Environmental Test Procedures)
III. Key Performance Parameters
Parameter Category |
Specifications |
Test Types |
Equipment Composition |
Combustion Chamber |
3.1 Test Types
- Vertical burning test
- Horizontal burning test
- 45° inclination burning test
- 60° inclination burning test (dedicated chamber)
3.2 Equipment Composition
- Modular system comprising:
- Combustion chamber
- Control system
- Test fixtures
3.3 Combustion Chamber
- Multi-functional chamber with shared structure for vertical/horizontal/45° tests
- Independent 60° test chamber
- Tempered glass observation window (front panel)
3.4 Burner System
- Bunsen burner configuration:
- Nozzle ID: Ф9.5±0.1mm
- Vapor nozzle: Ф0.9±0.03mm
- Air inlet height: 100±10mm
- Dual burners with 0°/45°/60°/90° adjustable angles
- Flame height adjustment: 20-100mm (test-dependent)
3.5 Timing System
- Multi-phase timing (burning/drip flame/smothering phases)
- 0.1s accuracy with 99.99h max range
3.6 Measurement Systems
Component |
Spécification |
Caliper |
1.0mm resolution |
Thermocouple |
K-type, 1.2-1.5mm diameter |
Temperature Meter |
0-1000°C range, 1°C resolution |
Stopwatch |
0.1s precision (backup) |
3.7 Fixture System
- Stainless steel fixtures with orientations:
- Horizontal test frame
- Vertical test frame
- 45°/60° inclined frames

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.