Detailed Product DescriptionBias Voltage Range:0 ~ 500mvMeasuring Range:0.1~10000 Ng/μlTemperat

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenu

Detailed Product Description

Bias Voltage Range:0 ~ 500mvMeasuring Range:0.1~10000 Ng/μl
Temperature Control Range:Room Temperature ~ 1000 ℃Temperature Control Accuracy:±1°C
Measurement Accuracy:Sample Concentration (ng/μl) 0.2 RSD(%)35 Sample Concentration (ng/μl) 1.0 RSD (%)10 Sample Concentration (ng/μl) 100 RSD(%)5 Sample Concentration (ng/μl)1000 RSD(%)2Gas Source Requirements:General Nitrogen And General Oxygen
Power Supply Voltage:AC 220V±10% 50Hz±10% 3.5KWDimensions:Host :410×350×75(mm) Temperature Control: 530×420×360(mm) Stirrer:290×270×360(mm) Injector:350×130×140(mm)
Highlight:

Easy To Operate Chloride Analyzer

Microcoulomb Sulfur Chloride Analyzer

Product Description

The Microcoulomb Sulfur Chloride Analyzer is designed and manufactured according to SH/T 0253. It applies microcoulomb analysis technology, uses oxidation method to oxidize the sample into titratable ions through the cracking furnace, and titrates in the titration cell. According to Faraday's law, calculate the sulfur content in the sample, which is suitable for light petroleum products with a boiling point of 40-310°C. Samples with a sulfur content ranging from 0.5 to 1000ppm, and samples with a sulfur content greater than 1000ppm should be measured after dilution. This instrument can also measure the content of chlorine.

Technical Features

Man-machine direct dialogue, easy to operate

The computer controls the whole process of analysis and data processing, displays the working status of the whole process, and saves or prints the parameters and results as required.

International popular circuits and imported components are used to reduce the noise of the instrument and improve the detection sensitivity.

It has the characteristics of stable and reliable performance, easy operation, high analysis precision and good repeatability.

Paramètres techniques

Bias voltage range0 ~ 500mv
Measuring range0.1~10000 ng/μl
Temperature control rangeroom temperature ~ 1000 ℃
Temperature control accuracy±1°C
measurement accuracy

Sample concentration (ng/μl) 0.2 RSD(%)35

Sample concentration (ng/μl) 1.0 RSD (%)10

Sample concentration (ng/μl) 100 RSD(%)5

Sample concentration (ng/μl)1000 RSD(%)2

Gas source requirementsgeneral nitrogen and general oxygen
Power supply voltageAC 220V±10% 50Hz±10%
Power3.5KW
Dimensions

Host :410×350×75(mm)

Temperature control: 530×420×360(mm)

Stirrer:290×270×360(mm)

Injector:350×130×140(mm)


Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.