Single Cable Vertical Flame Tester - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466
Produits

Single Cable Vertical Flame Tester

Main use  G233 Fabric vertical combustion tester is mainly used to evaluate the combustion character

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenu

Introduction

Single Cable Vertical Flame Tester is used for the vertical flame propagation of a single insulated wire or cable is a bench scale test to determine the resistance of a single cable to a 1kW flame application. It conforms to IEC60332-1-2 (flame propagation) and IEC60332-1-3 (test for flaming droplets).


Main use

G233 Fabric vertical combustion tester is mainly used to evaluate the combustion characteristics of plastics and other non-metallic materials in fire. It is suitable for lighting equipment, low-voltage electrical appliances, household appliances, machine tools,electrical tools, electronic instruments, electrical instruments, electrical connectors and accessories and other electrical and electronic products and components of the research,production and quality inspection departments, but also suitable for insulation materials,engineering plastics or other solid combustible materials industry. In addition, it can also be used by the plastics industry, inspection departments and scientific research institutions.


Meet the standard

GB/T 2408-2008.

GB/T 5455.

GB/T 13488.

GB/T 5169.16-2008.

GB/T 8332-2008.

GB/T 5169.17-2008.

ASTM D4804.

ISO 1210.

ISO 9772. ISO 9773.

IEC 60332-1-1~3:2004


Main parameter

1. Combustion Angle: 0°-45°

2. Power: 50W, 500W, 1000W

3. Flame application time: 0——999.9S

4. Flame height: 20±1mm, 40±2mm, 50—— 60mm

5. Temperature measurement distance: 10±1mm, 55±1mm, 95


Technical parameters

1.Stainless steel box, the height of 1300mm, width of 300mm, depth of 450mm.

2.Two stainless steel rods, can bind single wire cable or optical cable sample.

3.1KW mixed standard burner, can provide the standard test fire source.

4.Regulating gas and air flow rate of the rotor flow meters.

5.Pressure gauge and pressure relief valve to ensure that the pressure output is 0.1MPA.

2.jpg

3.jpg



Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.

Précédent :Il est parti
Page suivante:Il est parti

Message en ligne

Détails de contact

Téléphone de l'entreprise

+86-21-6420 0566

Heures de travail

Du lundi au vendredi

Téléphone portable:

13816217984

Courriel :

info@qinsun-lab.com

Code QR