Humidified Tandem Differential Mobility Analyzer - Qinsun
Fabricant professionnel d'instruments de détection
Ligne directrice nationale de consultation :+86 021-64208466

Humidified Tandem Differential Mobility Analyzer

The Humidified Tandem Differential Mobility Analyzer (DMA) system has two differential mobility anal

Courriel : info@standard-groups.com

Contenu

The Humidified Tandem Differential Mobility Analyzer (DMA) system has two differential mobility analyzers and a humidification section in between. Aerosol from the ambient atmosphere or from the built-in aerosol generator can be classified by the first DMA to produce a monodisperse aerosol for size analysis by the second DMA to determine the growth in particle size as a function of relative humidity.
 
Structure
 · Built-in Atomizer Aerosol Generator
· Electrical Ionizer
· Differential Mobility Analyzer (DMA)
· Electrical Mobility Spectrometer
· Condensation Particle Counter (CPC)
· Humidity Conditioner
· Data analysis software
 
Features
 · High stability atomizer aerosol generator
· High accuracy aerosol humidity conditioner
· Wide range, high resolution DMAs
· Patented dual-reservoir CPCs
· DMS and SMS data analysis software
· User friendly user interface with touch screen display
· Automatic data logging
 image.png
Application
 · Study of the hygroscopic growth of aerosols for accurate deliquescence and efflorescence measurements. 
· Other aerosol studies by the TDMA method.
 
Paramètres techniques

Overall Specifications of the Model 1040XP HTDMA*
Aerosol Generator (Part 1 of system)460 mm (H) x 610 mm (D) x 525 mm (W)
Part 1/Part 2 Total Weight100 lbs (45 kg)/ 140 lbs (60 kg)
Power Requirements (Part 1)115 or 230 VAC, 50-60 Hz, single phase, 250 W max, 160 W steady
Humidity Conditioner/Spectrometer (Part 2)460 mm (H) x 610 mm (D) x 525 mm (W)
Power Requirements (Part 2)100- 240 VAC, 50-60 Hz, single phase, 500 W max, 400 W steady
Operating Aerosol Pressure800 to 1050 mbar absolute pressure
Ambient Temperature Range10 to 35 ºC
Ambient Humidity Range0-90% RH, non-condensing


Polydisperse Aerosol Generation System
Single-Jet AtomizerStainless Steel Construction
Pressure5 to 60 psig (5 to 415 kPa gage), controlled by manual pressure regulator
Aerosol Flow RateTypical 3 L/min @ 35 psig (240 kPa gage)
Volume Mean Droplet Diameterabout 2 µm (GSD< 2.0)
Aerosol Size Range10 to 2000 nm
Aerosol Concentration> 107 particles/cm3 (typical for NaCl)
DryerDiffusion type (NafionR membrane requires dry comp. air, -20 ºC dew point)


Humidity Conditioner
Relative Humidity Control Range10 to 93% with user-selected set point in 1% intervals
Flow Rate1 to 10 L/min
RTD and Dew Point Accuracy± 0. 2 ºC
RH Accuracy± 1.5% for chilled mirror sensor; ± 2.5% for capacitive sensor
RH control stability± 1.2% (typical)
Response Time for < 10% ΔRH< 3 min (typical)
Water Reservoir Heater Control25 to 50 ºC in 5 ºC intervals
SaturatorNafion® Humidifier with DI water closed loop circulation
DryerDiffusion type (Drierite® desiccant)

Disclaimer: Le contenu ci-dessus est destiné à des fins de référence et de communication uniquement entre les initiés de l'industrie, et ne garantit pas son exactitude ou son exhaustivité. Conformément aux lois et règlements pertinents et aux règlements de ce site Web, les unités ou personnes qui achètent des articles connexes doivent obtenir des qualifications et des conditions de qualification valides.